first initial inspection
quantity
Manufacturer Part Number
factory
date code
batch number
RoHS and MSL
Physical Status Check
Package
barcode verification
Stage 2: Detailed Inspection
Performed by a senior quality inspector Validate the first stage inspection
Use a high-power microscope to inspect components for compliance
Anti-counterfeiting inspection
Dimensional inspection
Electrical performance test to verify the circuit value of the capacitor
Chip surface chemical reagent test
Acetone test
Take pictures and record in the database
Use IDEA/ERAI information as a reference
Third, by virtue of the long-term and good cooperative relationship with the top testing institutions in the industry, Intour can provide customers with more professional and in-depth testing projects, including:
Unpacking test
X-ray test
XRF
toughness test
EDX/EDS
CSAM test
Electrical performance test